Synergy Workforce - Specification sheet
SynergyRecommended Specification
- Windows Server 2016 or higher
- Virtual environments supported (VMware / Hyper-V)
- Microsoft SQL Server 2017 or higher (Mixed Mode)
- IIS 10 or higher
- .NET Framework 4.8 or higher
- Intel Xeon Quad-Core processor or higher
- 8 GB RAM minimum (16 GB recommended)
Recommended storage layout:
- C: 100 GB - Windows + SQL + application files
- S: 100 GB - SQL database files
- L: 50 GB - SQL log files
If hosting outside your domain, ensure the provider meets the above software, storage, and security requirements.
Hardware Prerequisites
- Adam Fire Link - IP Type: Static - Ports (in/out): 1025 β 5168 - Remote Address: Required - Notes: Inbound & outbound
- IR (HandPunch) - IP Type: Static - Ports (in/out): 3001 - Remote Address: If hosted - Notes: NAT/PAT required
- Suprema BioStar 2 - IP Type: Static/DHCP - Ports (in/out): 51211-51212 - Remote Address: Required - Notes: Inbound & outbound
- SY400 (Offline) - IP Type: Static - Ports (in/out): Per-device - Remote Address: If hosted - Notes: Unique port per device
- SY400 (Online) - IP Type: Static - Ports (in/out): Per-device + 3736 - Remote Address: Required - Notes: 3736 server-side
- Synergy A - IP Type: Static/DHCP - Ports (in/out): 3939 - Remote Address: Webservice URL
- Synergy Face - IP Type: Static/DHCP - Ports (in/out): 3636 - Remote Address: Webservice URL
- Synergy Touch - IP Type: Static/DHCP - Remote Address: Webservice URL
- TeamViewer 10
- SYxxx - IP Type: Static - Ports (in/out): +3734 per device - Remote Address: Required - Notes: Unique per device
- Thermal Kiosk - IP Type: Static - Ports (in/out): 8080 - Remote Address: If hosted - Notes: NAT/PAT for multiple devices
- ANPR Camera - IP Type: Static - Remote Address: Webservice