Fix for the SECURE IO2 freezing issue = force the speed between secure IO 2 and Master to 9600 bauds

SWF
Fix for the SECURE IO2 freezing issue = force the speed between secure IO 2 and Master to 9600 bauds:

Requirements :
SWF 4.2.3 minimun
SECURE IO 2 firmware version “SIO2_Upgradeimage_V1_3_1_20220613_192500C.bin”

A- In BIOSTAR 2
  1. Upgrade the secure IO2 to version “SIO2_Upgradeimage_V1_3_1_20220613_192500C.bin
  2. After the upgrade change the baud rate of the master to 9600 otherwise the secure IO2 won’t connect 

B- IN SWF:

1. In the device settings, change the baud rate here to 9600 (this new parameter appears in SWF from version 4.2.3 and appears only for SUPREMA devices)

2. Sync the device/master from SWF/Maintenance

3. Test the door

Fix for the SECURE IO2 freezing issue = force the speed between secure IO 2 and Master to 9600 bauds