Suprema CoreStation 20
Synergy Workforce supports the Suprema CoreStation 20 (CS-20) from version 5.33. It replaces the older SY400 controllers and uses RS-485 and Wiegand readers for access control.
Reader numbers
From version 6.2.0, each reader on a CoreStation must have a different reader number.
LEDs on non-Suprema readers
From version 6.7.0, the Wiegand LED outputs for non-Suprema readers on a CoreStation 20 can be set in Devices > Add/Edit Device, on the CoreStation Settings tab. The LED settings are shown there when the device model is CoreStation 20. This applies to the CoreStation 20 only, not the CoreStation 40 or other models. The length and pulse pattern of a Wiegand reader's LED can't be set.
The LED settings are sent to the device automatically if automatic sync is on for it (Maintenance > Suprema 2 Devices, Settings tab). Otherwise, run Sync Access Control from Maintenance > Suprema 2 Devices after setting them up.
Readers that stop working (master and slave)
From version 6.7.0, RS-485 slave devices connected to a Suprema master can be inspected and repaired from Synergy Workforce. Use this when a slave loses its pairing with the master and stops working.