Synel Workforce 6.7.0 (November 2026)
SWFAdministrator actions
- Default muster point: Review the default muster point after upgrading. The upgrade selects an existing point, or creates a virtual one if none exists, and assigns employees who have no muster point.
- Duplicate emergency devices: Manually correct existing devices with duplicate Device IDs and IP addresses. The upgrade does not correct these records.
- Suprema leavers: The access-date fix reaches people already on devices during the next nightly template sync. Re-send their templates to apply it sooner.
- CoreStation 20 LEDs: Settings are sent automatically when automatic sync is enabled in Maintenance > Suprema 2 Devices > Settings. Otherwise, run Sync Access Control after configuring them.
- Lucca: Update the Lucca Integration service to apply the error-handling fix.
Emergency Control
Emergency Control now organises evacuation, roll call and reporting around muster points.
- Emergency Devices: Manage emergency devices on a dedicated page under the Emergency menu, using a setup wizard. They no longer appear on the main Devices page. Users with existing access to both Emergency and Devices receive access automatically.
- Virtual muster points: Create muster points without a physical device.
- Default muster point: People without an assigned point use the default. It can be renamed and edited, but cannot be deleted or disabled. Fire Marshal assignments are optional.
- Employee records: The Emergency tab is now called Emergency Exit and shows the employee's muster point, location and Fire Marshals. Previous Fire Marshal settings remain visible as read-only information.
- Visitors: Visitors use their host's muster point, or the default if they have no host. Reassign on-site visitors before deleting or deactivating their host.
- Evacuation Panel: Filter by muster point, last known building and last known location.
- Roll Call Panel: View each person's latest attendance or access control record and print the panel.
- Roll Call Report: Added a report grouped by muster point, with a Fire Marshal filter. It includes Fire Marshals, employees, visitors and their hosts, and security guards.
- Emergency emails: When Fire Link or the Evacuation Panel triggers an emergency, the Roll Call Report is emailed to the Fire Marshals assigned to the emergency devices.
- Post-Emergency Report: View average time to reach the muster point, roll-call completion time and total emergency duration. Available from the Evacuation Archive and Advanced Reporting.
- Emergency archive: Updated the archive to match the new Emergency Control screens.
- Setup guidance: Users with read/write access see a banner linking to incomplete setup items. It can be dismissed for the session.
Other new features
- First Aiders: Mark employees as First Aiders and identify them by an icon on the PIP screen and access control presence panel.
- CoreStation 20 reader LEDs: Configure LEDs for connected non-Suprema Wiegand readers in the CoreStation Settings tab. LED duration and pulse pattern cannot be configured.
- Suprema device pairing: Check and repair lost RS-485 master/slave pairings from Synergy Workforce.
Improvements
- Report filters: Added Job Role and Line Manager to the standard employee filter used by most reports.
- Activity-group filters: Added to Activities By Client, Activities By Cost Centre, Activities By Employee, Activity Exceptions, Cost Detail, Job Costing Actual Vs Estimated By Activity, Job Costing Summary By Activity, Job Costing Summary By Employee, Scheduled Activities, Scheduled Activities Vertical and Weekly Scheduled Activities With Duration.
- Pay-rate filters: Added to Activities By Cost Centre, Cost Centre and Cost Centre By Employee.
- Cost-centre filters: Added to Cost Centre, Cost Centre By Employee and Time Pay Type Overview.
- Evalu-8: Swipe exports now send Site ID instead of device name. Device name remains the fallback when Site ID is empty.
- Duplicate identifiers: Employee No and Biometric ID errors now identify the employee already using the value and link to their record where access allows.
- Monitoring screens: Added refresh indicators to Access Control and ANPR monitoring. Disable them in System Setup > Options > User preferences.
- Fire Marshals: The PIP filter includes muster-point Fire Marshals. Fire reports include both previous and new Fire Marshal assignments.
Fixes
- Suprema leavers: Employees retain access until midnight at the end of their leave date, including where a security group end date overrides it.
- Suprema Auto Mode: Holidays are now applied, and changes to upcoming holidays trigger synchronisation. Suprema access time zones still ignore holidays.
- Employee imports: Changes to employee-code capitalisation now update the existing employee rather than causing a duplicate error. One invalid record no longer stops later records. Applies to Lucca, Sage HR, People First, Rotageek, Staffology, Cascade and Atmos.
- Lucca: Fixed absence imports for customers with large user numbers and improved messages for invalid or incomplete data.
- Salto: Fixed routers being incorrectly marked unhealthy and repeatedly reconnected.
- Emergency devices: Prevented creation of duplicate Device IDs and IP addresses that could leave devices impossible to delete.
- Mustering status: Status now follows the employee's most recent transaction.
- Fixed errors generating the Emergency Archive Report and deleting employees.
Known issue
- Fourth integration: The first import on an employee's leave date marks them inactive, preventing clocking on their final day. A fix is in development.